Sign In | Join Free | My webtextiles.com
China Shenzhen Kinda Technology Co., Ltd logo
Shenzhen Kinda Technology Co., Ltd
Shenzhen Kinda Technology Co., Ltd
Active Member

7 Years

Home > Single Phase Variable Frequency Drive >

Constant Pressure Single Phase Variable Frequency Drive 1AC 0.4KW - 4KW

Shenzhen Kinda Technology Co., Ltd
Contact Now

Constant Pressure Single Phase Variable Frequency Drive 1AC 0.4KW - 4KW

  • 1
  • 2

Brand Name : Kinda

Model Number : KD388

Place of Origin : China

MOQ : Negotiable

Price : Negotiable

Payment Terms : T/T

Supply Ability : Adequate inventory

Delivery Time : 5~8 Day

Start Up : Simple Parameter Setting, One-button Start Automatic Addition And Subtraction Pump Control

PCB Protection : Spray Three Anti-paint To Protect The Circuit Board Intelligently And Efficiently

Way Of Communication : Standard Modbus Communication

Run : Smooth Main/slave Switching, No Change In Water Pressure

Installation : Simple Wiring Installation

Control : Main/slave Control Energy Saving

Contact Now

220V~240 Constant Pressure Single Phase Variable Frequency Drive 1AC 0.4KW~4KW

When the water supply automatic control system works, the equipment detects the pressure change of the water supply pipe network when the water consumption changes through the high-sensitivity pressure sensor installed on the water supply pipe network, and continuously transmits the changed signal to the inverter, and judges the operation and setting by the microcomputer. After the pressure is compared, the controller sends a command to change the frequency. The controller changes the speed of the water pump motor and the number of enabled pumps by changing the frequency, automatically adjusting the peak and valley water consumption, and ensuring the water supply pipe network pressure is constant to meet the user's water demand.

Constant Pressure Single Phase Variable Frequency Drive 1AC 0.4KW - 4KW

Function code Default value Set value Description
F1-11 1 I# inverter 1 1# inverter (master), it must connect the pressure sensor.
2# inverter 2 2# inverter (slave / standby master), connect the pressure senor.
3# inverter 3 3# and 4# inverters (slave).
4# inverter 4 Warning: the address of each inverter cannot be the same, otherwise, the system will work abnormally.
F0-00 1 2 Multiple pumps system
F0-01 0.4MPa Customer set 1. Please set it correctly based on requested pressure, the unit is MPa, 1MPa=10bar.
2. Most of the family used systems, the pressure is 0.3~0.4MPa (3~4bar)
F0-02 80% Customer set Wake up pressure; it is the percentage of F0-01.
F0-03 0 0 It must be set as “0” while use 0~10V remote pressure gauge.
1 It must be set as “1” while use 4~20mA pressure transducer.
F0-04 1.6MPa 1.6MPa 1. To set the maximum measure range of pressure transducer.
2. It must be set correctly, otherwise it may cause pressure is inaccurate.
F0-25 300Min Customer set To set the running time as master pump, when time arrive, it switches to next pump as master.
When set F0-25=0, this pump will only work as slave pump.

Constant Pressure Single Phase Variable Frequency Drive 1AC 0.4KW - 4KW


Product Tags:

single phase vfd drive

      

single phase motor drive

      
Quality Constant Pressure Single Phase Variable Frequency Drive 1AC 0.4KW - 4KW for sale

Constant Pressure Single Phase Variable Frequency Drive 1AC 0.4KW - 4KW Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Kinda Technology Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)